NL50SMilitary Grade & Industrial Series NL50 (50 Watt-Single)

.38 Inch Profile
Synchronization
N +1 Redundancy
Remote Turn-On  (TTL)
Output Over-Voltage Trim Pin
Over-Temperature Protection
Output Over-Voltage Protection
Over-Current Protection
M Version-100% Environmental Screening
Built-In Test (Output Power Good)
Environmental - Unscreened (I) or Screened (M)
Options Available:
  • EMI Filter
  • Pins Out Side of Unit
  • Pins Out Bottom of Unit
  • Pins Out Top of Unit
  • Through Hole Inserts (STD Threaded)
  • M2.5 Inserts
Environmental Screening
  M-Grade Environmental Screening   I-Grade Environmental Screening
  Stabilization Bake +125°C for 24 hours Similar to MIL-STD 883,
M1008.2, Condition B
  Burn-In 16 Hours @ +85°C min
Final Testing  
   
  Temperature Cycling 10 Cycles -55°C to +125°C, (Transition Period 36 minutes.),
Similar to MIL-STD-883, M1010, Condition B
     
           
Burn-In 160 Hours @ +85°C min.
  Final Testing        

 

Military Grade Selection Guide Data Sheet
Specifications subject to change without notification.
Standard Output Models
Nominal Output Voltage (Volts) Output Current
(Amps)
Unscreened
Industrial (I0
Screened
Military Grade (M)
2 10.0 NL50SI/2-A NL50SM/2-A
3.3 10.0 NL50SI/3.3-A NL50SM/3.3-A
5 10.0 NL50SI/5-A NL50SM/5-A
5.2 9.6 NL50SI/5.2-A NL50SM/5.2-A
12 4.2 NL50SI/12-A NL50SM/12-A
15 3.3 NL50SI/15-A NL50SM/15-A
       
See Data Sheet for Configuration with Options